Product Name: Noninvasive Continuous Blood Pressure Monitor
Series Number: BP100A
Product Highlights:
1 Non-invasive and safe, painless and stress-free, without any risk of discomfort, injection, thrombosis or injury to the patient.
2 Continuous monitoring the radial artery on the wrist to demonstrate real time artery blood pressure (ABP) waveform with pulserate (PR).
3 Ready to use without calibration required, fast and accurate measure beat to beat SBP, DBP, MBP, PR value with waveform.
4 Movement tolerant, monitoring can be maintained under a wide degree of patient movement, such as not influenced by vasomotion, body movement or external force.
5 It can provide continuous and accurate measurements under non-optimal conditions, such as low perfusion and weak pulse from cardiogenic shock.
6 It can be used for prolonged monitoring of patient; it has no discernible effect on blood circulation with nerve conduction.
7 It has multi-parameters function, such as - output port to compatible with other monitors.
Key Indicators
1 Measuring Range:
Sys.: 40-250mmHg Dia.: 15-215mmHg
Mean: 30-250mmHg PR: 30-250bpm
2 Resolution of Measurement:
Blood Pressure: 1mmHg Pulse Rate: 1 beat/min
3 Alarms: Physiological -medium priority Technical - low priority
Physical Parameters
Size: 318mmx 152mm x 264mm Weight: 5.5kg
Operating Environmental
Temperature: 0℃ to 40 ℃
Humidity: ≤80%
Altitude: 70 - 106 kPa
Power Requirements
AC input: 100 to 240 VAC (50Hz / 60Hz)
DC output: 12VDC
Application:
WristAP® BP100A & BP100B is developed for overcoming shortcomings of the invasive artery blood pressure and continuous measurment operation difficulties with thrombosis and other complications risks of invasive monitoring during Emergency Department(ED), Operating Theatre(OR), Intensive Care Unit (ICU), as well as Anesthesiology, etc.
It is acknowledged by clinical physicians and predicts BP100 is promising; it would be great demandin market of the real-time artery blood pressure monitoring field. More details on application are given below:
1. It is primarily applicable to non-invasive continuous beat to beat radial artery blood pressure monitor; and it also canbe used in anesthetic depth monitoring.
2. It is used for any occasion where invasive arterial lines are not indicated and non invasive blood pressure is not sufficient; the patients who are not suitable for vascular oscillometric measure; the patients who are undergoing non-optimal conditions, low perfusion or nervous and restless, but those who must get a fast and accurate for long duration of monitoring continuous BP waveforms in a beat by beat manner.
3. It is applied to scientific research, monitor response to therapy on hypertension, continuous monitor hypertension; it also can be used for emergency treatment during transporting.
4. It possesses anti-defibrillation function and can be connected with electrosurgical equipment.
4. It is frequently used in ED, ICU, or cardiology, ambulance, and battlefield.